Color machine auxiliary equipment installation

Users must use oil-free air compressor without water, and configure the coarse filter(our company has been equiped).Machine pneumatic components must be separated by the corresponding diameter galvanized pipes, rubber hoses or grades higher pipeline connection. Air compressor is recommed to install isolation room near the machine(not more than 15 meters )  so as to reduce noise and to guarantee supply sufficient air pressure of the machine.

Color sorters are equipped with filters, and its temperature is normally between 0 ℃-40 ℃, in the winter (especially in the northern areas), the room temperature will drop below 0 ℃, so it should be air-dried at the end of the operaton,and taken warming  measures to keep the room temperature at 0 °c or above. Otherwise, it may cause the filter and pipes to be frozen , so that not only can clog the air flows, and may damage the filter element.

Air compressor located areas must be well ventilated, clean, flat on the ground, low humidity. Ambient temperature is below 40℃, and keep the space 80cm far away from wall to maintain, note that outlet outward for easy discharge, but also to avoid direct sunlight and rain.

Coarse filters should be installed on the air compressor or gas tank outlet, in order to ensure the filter's function displayed fully.

If you find the pressure gauge on the color sorter shows the pressure decreased significantly (less than 0.1MPa, color sorters working pressure is between 0.25-0.35MPa), should replace the filter cartridge. Dont take off the filter cartridge otherwise they will be seriously affected and damaged the filter elements and ejector valve on the precision filters.

Pipe connections from the air compressor, in order to avoid the effect of vibration, can be connected with a rubber hose.

Before all the pipe connections, pipe in debris and dust must be cleaned or damaged valves directly.

The debris and dust must be cleaned before all piping connected or damage injection valve directly .